Skip navigation
Please use this identifier to cite or link to this item: https://libeldoc.bsuir.by/handle/123456789/38981
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAbbood, N. A.-
dc.contributor.authorAlhamd, M. W.-
dc.contributor.authorAlqaisi, Z. A.-
dc.date.accessioned2020-05-27T11:35:22Z-
dc.date.available2020-05-27T11:35:22Z-
dc.date.issued2020-
dc.identifier.citationAbbood, N. A. The radiation doses diagnostic X-rays and quality assurance tests for devices / N. A. Abbood, M. W. Alhamd, Z. A. Alqaisi // BIG DATA and Advanced Analytics = BIG DATA и анализ высокого уровня: сб. материалов VI Междунар. науч.-практ. конф., Минск, 20-21 мая 2020 года: в 3 ч. Ч. 1 / редкол.: В. А. Богуш [и др.]. – Минск : Бестпринт, 2020. – С. 183–194.ru_RU
dc.identifier.isbn978-985-90533-7-5-
dc.identifier.urihttps://libeldoc.bsuir.by/handle/123456789/38981-
dc.description.abstractRight now estimated the passage surface portions of patients which result from ordinary radiography (chest, head, belly, appendages) by picking instruments in AL-sader. A gathering of patients (10 patient) are chosen for every assessment and the mean portions are determined. The surface dosages with understanding squeezed (ESDpp) were estimated utilizing thermoluminescence dosemeter (TLD) and passage surface dosages with nonattendance of patient (ESDpa) by utilizing versatile ionizing chamber Sweden made . We found that the perusing of thermoluminescence dosemetry (TLD) is more than normal estimation of ionization chamber which are utilized and the diverse originated from the dispersing of radiation in understanding body, the dissipating coefficient to all tests are determined and we found that coefficient extend between(1.05 – 1.1) and this worth is near global qualities which equivalent to (1.09) . The patient dosages right now contrasted and worldwide qualities, it is discovered that our qualities are more noteworthy by a range between (1.2-1.7) in many instruments , and the range is shut to (1) at whatever point the instrument is new and the experience of radiographer is acceptable, The estimations of this examination are talked about in detail . For the significance of (Quality Assurance) we measure seven tests for three instruments in particular, and these tests are (– voltage Test – Test of current Linearity – Test of Linearity of Time – Half Value Layer Test – Beam Alignment Test – Optical and Radiation Field Congruence Test – Focal Spot Test ) , The tests demonstrated that the gadgets (F, C) breezed through quality confirmation assessments are unfit for work right now, yet the (A) didn't finish most assessments of value affirmation, accordingly prescribed not to utilize this machine.ru_RU
dc.language.isoenru_RU
dc.publisherБеспринтru_RU
dc.subjectматериалы конференцийru_RU
dc.subjectdiagnostic X-raysru_RU
dc.subjectthe radiation dosesru_RU
dc.subjectquality assurance testsru_RU
dc.titleThe radiation doses diagnostic X-rays and quality assurance tests for devicesru_RU
dc.typeСтатьяru_RU
Appears in Collections:BIG DATA and Advanced Analytics = BIG DATA и анализ высокого уровня : материалы конференции (2020)

Files in This Item:
File Description SizeFormat 
Alqaisi_The.pdf732.62 kBAdobe PDFView/Open
Show simple item record Google Scholar

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.