dc.date.issued2024-
dc.identifier.citationNonlinear Microwave Device LabVIEW Automatic Test Bench: Double-Frequency IMD3 Characterization / Xin Cheng, Fayu Wan, VюMordachev, Е. Sinkevich [et al.] // Progress In Electromagnetics Research B. – 2024. – Vol. 108. – P. 47–59.en_US
dc.identifier.urihttps://libeldoc.bsuir.by/handle/123456789/58934-
dc.description.abstractThe active component nonlinear (NL) effect causes undesirable RF and microwave system electromagnetic interference (EMI) problems which penalizes the communication system performance by signal distortion. Therefore, a relevant NL component measurement method is needed to predict the transceiver system EMI effect. However, the NL measurement characterization of RF and microwave active devices remains a fastidious and time cost task. An innovative NL test bench automatized by LabVIEW®control interface is featured in this research work. The design technique of the NL test methodology is described. The developed automatic test bench is tested with a microwave power amplifier (PA) operating at 2.4 GHz based on double-frequency (DF) method. The experimental test setup including the LabVIEW®test control parametrization and data acquisition is described. The test bench effectiveness was assessed by the third-order intermodulation (IMD3) PA measurement with DF method. The theoretically calculated and measured IMD3 amplitudes based on DF input signal are in very good correlation. Thanks to its advantages in terms of simplicity, flexibility, and time cost, the innovative NL automatic test bench is very useful for transceiver system EMI analyses.en_US
dc.language.isoenen_US
dc.publisherElectromagnetics Academyen_US
dc.subjectпубликации ученыхen_US
dc.subjectelectromagnetic interferenceen_US
dc.subjectmicrowaveen_US
dc.subjectintermodulationen_US
dc.subjectfrequency methoden_US
dc.titleNonlinear Microwave Device LabVIEW Automatic Test Bench: Double-Frequency IMD3 Characterizationen_US
dc.typeArticleen_US
dc.identifier.DOI10.2528/PIERB24053005-
Appears in Collections:Публикации в зарубежных изданиях

Files in This Item:
File Description SizeFormat 
Mordachev_Nonlinear.pdf116.65 kBAdobe PDFView/Open
Show simple item record Google Scholar

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.