Skip navigation
Пожалуйста, используйте этот идентификатор, чтобы цитировать или ссылаться на этот ресурс: https://libeldoc.bsuir.by/handle/123456789/37243
Название: Surface Enhanced Raman Spectroscopy of Lactoferrin Adsorbed on Silvered Porous Silicon Covered with Graphene
Авторы: Zavatski, S. A.
Khinevich, N. V.
Girel, K. V.
Redko, S. V.
Kovalchuk, N. G.
Komissarov, I. V.
Lukashevich, U. A.
Semak, Igor
Mamatkulov, Kahramon
Vorobyeva, Maria
Arzumanyan, G. M.
Bandarenka, H. V.
Ключевые слова: публикации ученых;surface enhanced Raman scattering;silver;porous silicon;graphene;lactoferrin;attomolar concentration
Дата публикации: 2019
Издательство: MDPI
Описание: Surface Enhanced Raman Spectroscopy of Lactoferrin Adsorbed on Silvered Porous Silicon Covered with Graphene / Sergey Zavatski [and other] // Biosensors. – 2019. – Vol. 9. – P. 34 (19 pages). – DOI: 10.3390/bios9010034.]
Аннотация: We registered surface enhanced Raman scattering (SERS) spectra of the human lactoferrin molecules adsorbed on a silvered porous silicon (por-Si) from 10^-6–10^-18 M solutions. It was found that the por-Si template causes a negative surface potential of silver particles and their chemical resistivity to oxidation. These properties provided to attract positively charged lactoferrin molecules and prevent their interaction with metallic particles upon 473 nm laser excitation. The SERS spectra of lactoferrin adsorbed from 10^-6 M solution were rather weak but a decrease of the concentration to 10^-10 M led to an enormous growth of the SERS signal. This effect took place as oligomers of lactoferrin were broken down to monomeric units while its concentration was reduced. Oligomers are too large for a uniform overlap with electromagnetic field from silver particles. They cannot provide an intensive SERS signal from the top part of the molecules in contrast to monomers that can be completely covered by the electromagnetic field. The SERS spectra of lactoferrin at the 10^-14 and 10^-16 M concentrations were less intensive and started to change due to increasing contribution from the laser burned molecules. To prevent overheating the analyte molecules on the silvered por-Si were protected with graphene, which allowed the detection of lactoferrin adsorbed from the 10^-18 M solution.
URI: https://libeldoc.bsuir.by/handle/123456789/37243
Располагается в коллекциях:Публикации в зарубежных изданиях

Файлы этого ресурса:
Файл Описание РазмерФормат 
Zavatski_Surface.pdf4.72 MBAdobe PDFОткрыть
Показать полное описание Просмотр статистики Google Scholar

Все ресурсы в архиве электронных ресурсов защищены авторским правом, все права сохранены.