https://libeldoc.bsuir.by/handle/123456789/38981
Title: | The radiation doses diagnostic X-rays and quality assurance tests for devices |
Authors: | Abbood, N. A. Alhamd, M. W. Alqaisi, Z. A. |
Keywords: | материалы конференций;diagnostic X-rays;the radiation doses;quality assurance tests |
Issue Date: | 2020 |
Publisher: | Беспринт |
Citation: | Abbood, N. A. The radiation doses diagnostic X-rays and quality assurance tests for devices / N. A. Abbood, M. W. Alhamd, Z. A. Alqaisi // BIG DATA and Advanced Analytics = BIG DATA и анализ высокого уровня: сб. материалов VI Междунар. науч.-практ. конф., Минск, 20-21 мая 2020 года: в 3 ч. Ч. 1 / редкол.: В. А. Богуш [и др.]. – Минск : Бестпринт, 2020. – С. 183–194. |
Abstract: | Right now estimated the passage surface portions of patients which result from ordinary radiography (chest, head, belly, appendages) by picking instruments in AL-sader. A gathering of patients (10 patient) are chosen for every assessment and the mean portions are determined. The surface dosages with understanding squeezed (ESDpp) were estimated utilizing thermoluminescence dosemeter (TLD) and passage surface dosages with nonattendance of patient (ESDpa) by utilizing versatile ionizing chamber Sweden made . We found that the perusing of thermoluminescence dosemetry (TLD) is more than normal estimation of ionization chamber which are utilized and the diverse originated from the dispersing of radiation in understanding body, the dissipating coefficient to all tests are determined and we found that coefficient extend between(1.05 – 1.1) and this worth is near global qualities which equivalent to (1.09) . The patient dosages right now contrasted and worldwide qualities, it is discovered that our qualities are more noteworthy by a range between (1.2-1.7) in many instruments , and the range is shut to (1) at whatever point the instrument is new and the experience of radiographer is acceptable, The estimations of this examination are talked about in detail . For the significance of (Quality Assurance) we measure seven tests for three instruments in particular, and these tests are (– voltage Test – Test of current Linearity – Test of Linearity of Time – Half Value Layer Test – Beam Alignment Test – Optical and Radiation Field Congruence Test – Focal Spot Test ) , The tests demonstrated that the gadgets (F, C) breezed through quality confirmation assessments are unfit for work right now, yet the (A) didn't finish most assessments of value affirmation, accordingly prescribed not to utilize this machine. |
URI: | https://libeldoc.bsuir.by/handle/123456789/38981 |
ISBN: | 978-985-90533-7-5 |
Appears in Collections: | BIG DATA and Advanced Analytics = BIG DATA и анализ высокого уровня : материалы конференции (2020) |
File | Description | Size | Format | |
---|---|---|---|---|
Alqaisi_The.pdf | 732.62 kB | Adobe PDF | View/Open |